De-dietrich VIVADENS MCR 24_28 BIC Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Chaudière à eau De-dietrich VIVADENS MCR 24_28 BIC. DE DIETRICH VIVADENS MCR 24_28 BIC User Manual [en] [ru] [de] [es] [fr] [it] [cs] [pl] Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer

Résumé du contenu

Page 1 - MCR 24/28 BIC

VivadensENWall-hung gas condensing boilersMCR 24/28 BICUser Guide300024112-001-01

Page 2 - Contents

3 Description3.1 General descriptionWall-hung gas condensing boilers4 Heating and domestic hot water production with integrated DHWtank.4 High efficie

Page 3

The display indicates the state of the boiler and any errors. Thesymbols located above the function keys indicate their currentfunction.Pressing on an

Page 4

4 Operating the appliance4.1 Starting and stopping the boiler4.1.1. Start the boiler1. Check the water pressure in the installation.2. Open the gas va

Page 5 - 1 Introduction

4.1.2. Stopping the boiler1. Throw the boiler’s ON / OFF switch.2. Switch off the boiler electrical power supply.3. Close the gas valve.A000786-AT0001

Page 6 - 1.3.3. User’s liability

4.2 Changing the settings4.2.1. Changing the heating temperatureIf an outside temperature sensor or an OpenTherm controlsystem is fitted, the heating

Page 7 - 1.4 Homologations

4.2.3. Stopping the central heating or activatingthe Summer mode1. Press the D key.The symbol D and the current temperature are displayed.2. Press the

Page 8 - 2 Safety instructions and

4.2.4. Changing the domestic hot watertemperature1. Press the N key.The symbol N and the current temperature are displayed.2. Use the [+] and [-] keys

Page 9 - 2.2 Recommendations

4.2.5. Stopping domestic hot water production1. Press the N key.The symbol N and the current temperature are displayed.2. Press the key [-] several ti

Page 10 - 3 Description

To change these parameters, proceed as follows:1. Press key f several times until the symbol W flashes on the menubar.2. Press the S key to enter the

Page 11 - MCR 24/28 BIC 3. Description

If the temperature of the central heating water in the boiler falls toomuch, the integrated protection device switches itself on:4 If the water temper

Page 12 - 4 Operating the appliance

Contents1 Introduction ...41.1 Symbols used ...

Page 13 - 4.1.2. Stopping the boiler

5 Checking and maintenance5.1 General instructionsCAUTION4 An annual inspection is compulsory.4 We recommend taking out a maintenance contract.4 Maint

Page 14 - T000148-B

4 Clean the outside of the boiler using a damp cloth and a lightdetergent.CAUTIONOnly a qualified professional is authorised to clean theinside of the

Page 15 - T000141-A

4. Wait until the temperature drops below 40°C and the radiatorsseem cold before filling the central heating system.5. Open the disconnector valves.6.

Page 16 - T000143-A

2. Set the room thermostat as high as possible.3. Wait until the radiators are hot.4. Switch the boiler off.5. Wait around 10 minutes until the radiat

Page 17 - T000142-A

7. Open the bleed connection using the bleed key provided whilstkeeping a rag pressed against the connection.8. Wait until water comes out of the blee

Page 18 - T000307-A

6 Troubleshooting6.1 Error codes6.1.1. e01 - e02 - e07 - e09If one of the breakdown codes opposite is dispayed, check thehydraulic pressure:Case 1: Pr

Page 19 - T000138-A

6.1.4. Before contacting the installerBefore contacting the installerNote the following information on the appliance’s rating plate:4 Type of gas used

Page 20 - T000181-B

Problem Probable causes SolutionThe boiler is not working.The heating temperature settingis too low.Increase the value of parameter p1 or, if a roomth

Page 21 - T000155-A

7 Technical specifications7.1 Technical specificationsMCR BICBoilerHeating mode Nominal useful output 40/30 (min / max) kW 6.3 /25.3Nominal useful out

Page 22 - 5. Checking and maintenance

MCR BICMinimum pressure for 11 l/min(2)bar 0.5Water capacity litres 40Combustion products circuitConnection diameter mm 60/100Mass flue gas flow rate

Page 23 - 4. Switch the boiler off

4.4 Reading out measured values ...185 Checking and maintenance ...

Page 24 - T000183-A

8 Energy savings8.1 Energy savingsThis chapter contains:4 Energy-saving advice4 Advice on setting the room thermostat correctly8.1.1. Energy-saving ad

Page 25 - 6.1 Error codes

4 If you are using an ON/OFF type thermostat, reduce the watertemperature value (p1) in summer (e.g. 60 in summer and80 in winter).4 When setting an

Page 26 - T000258-A

9 Warranty9.1 GeneralYou have just purchased one of our appliances and we thank you forthe trust you have placed in our products.Please note that your

Page 27 - 170513 - 300024112-001-01

MCR 24/28 BIC 9. Warranty170513 - 300024112-001-0132

Page 30 - 8 Energy savings

AD001NU-AiDUEDI S.r.l.DE DIETRICH SERVICEBDR Thermea (Czech republic) s.r.owww.duediclima.itwww.dedietrich.czDistributore Ufficiale EsclusivoDe Dietri

Page 31 - 80 in winter)

3170513 - 300024112-001-01

Page 32 - 9 Warranty

1 Introduction1.1 Symbols usedIn these instructions, various danger levels are employed to draw theuser’s attention to particular information. In so d

Page 33 - MCR 24/28 BIC 9. Warranty

In the interest of customers, we are continuously endeavouring tomake improvements in product quality. All the specifications stated inthis document a

Page 34

1.4 Homologations1.4.1. CertificationsCE identification noPIN 0063BQ3009NOx < 60 mg/kWhMCR 24/28 BIC 1. Introduction170513 - 300024112-001-016

Page 35

2 Safety instructions andrecommendations2.1 Safety instructionsDANGERIf you smell gas:1. Do not use a naked flame, do not smoke, do notoperate electri

Page 36 - © Copyright

2.2 RecommendationsWARNINGOnly qualified professionals are authorised to work on theappliance and the installation.4 Regularly check the water pressur

Commentaires sur ces manuels

Pas de commentaire